Basic Operation & Standard Features
BASLER A600
f 3-15
DRAFT
Figure 3-6: Exposure Start Controlled with an ExTrig Signal
You can calculate the frame readout time with this formula:
Frame Readout Time = ( AOI Height x 15.28 µs ) + C
Where: C = 45.84 µs for monochrome cameras
C = 61.12 µs for color cameras
You can calculate the frame transmission time with this formula:
Frame Transmission Time = Packets/frame x 125 µs
On the A601f:
Minimum Transmission Start Delay = Readout Time
Maximum Transmission Start Delay = Readout Time + 125 µs
To calculate the transmission start delay on the A602f, use the following information:
If the transmission time is greater than the frame readout time:
Transmission Start Delay = 125 µs
If the transmission time is less than the frame readout time:
Transmission Start Delay = (Readout Time - Transmission Time) + 125 µs