7.3 Mechanical Stress Test Results
The A600f was submitted to an independent mechanical testing laboratory and subjected to the
stress tests listed below. After mechanical testing, the camera exhibited no detectable physical
damage and produced normal images during standard operational testing.
Test Standard Conditions
Vibration
(sinusoidal each axis)
DIN IEC 60068-2-6 10-58 Hz / 1.5 mm_58-500 Hz / 20 g_1 Octave/Minute
10 repetitions
Shock (each axis)
DIN IEC 60068-2-27 20 g / 11 ms / 10 shocks positive
20 g / 11 ms / 10 shocks negative
Bump (each axis)
DIN IEC 60068-2-29 20 g / 11 ms / 100 shocks positive
20 g / 11 ms / 100 shocks negative
Table 7-1: Mechanical Tests