Register Name: Strobe 0 Control
Offset from Base Address: 0x200
Field Bit Description
Presence Inq 0 Indicates the presence of the Strobe 0 signal control feature.
0 = not available 1 = available
The Strobe 0 control feature is available on all A600f cameras.
This field is read only.
---
1 ... 5 Reserved
On / Off 6 Sets whether the Strobe 0 signal is on or off.
0 = off 1 = on
Default = 0 on all A600f cameras
If this bit is 0, all other fields in this register are read only.
Signal Polarity
7 Sets the polarity of the Strobe 0 signal.
0 = low active 1 = high active
Default = 1 on all A600f cameras
Delay Value
8 ... 19 Sets the delay value for the Strobe 0 signal (see Section 3.10). The de-
lay value can range from 0 to 4095.
Strobe 0 Delay = (Delay Value Setting) x (1/1024 ms)
Default = 0 on all A600f cameras
Duration Value
20 ... 31 Sets the duration value for the Strobe 0 signal. The duration value can
range from 0 to 4095.
Strobe 0 Duration = (Dur. Value Setting) x (1/1024 ms)
Default = 4095 on all A600f cameras
Register Name: Strobe 1 Control
Offset from Base Address: 0x204
Field Bit Description
Same definitions and values as Strobe 0 Control.