4.2.4.7 Positive Offset
Purpose: To set the positive offset or to read the current positive offset setting. If you use OfsPos, set
OfsNeg to 0. See section 3.7 for more information on offset.
Type: This is a read or write command.
Read Command: Cmd-ID R/W-Flag Data Length Data
0x86 1 1 -
Response: Cmd-ID R/W-Flag Data Length Data
0x86 0 1 1 Byte
Write Command: Cmd-ID R/W-Flag Data Length Data
0x86 0 1 1 Byte
Response: None
Data Format: Byte 1 Negative offset setting
Data Range: The positive offset setting can range from 0x00 to 0xFF. Since the offset is
mostly negative, we recommend to set this value to 0.