Features AW00118501000
76 Basler racer Camera Link
Camera.ClPixelClock.SetValue( ClPixelClock_PixelClock48 );
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3.1 on page 15.
Setting the Camera Link Pixel Clock Using Direct Register Access
To set the Camera Link pixel clock speed via direct register access:
Set the value of the Cl Pixel Clock register for 32.5, 48, 65, or 83.5 MHz.
For more information about changing settings via direct register access, see Section 3.2 on
page 16.
You can use the pylon API to set the pixel clock speed to 32.5, 48, 65, or
83.5 MHz. These are the only valid values for the pixel clock speed. If you attempt
to use the API to set the clock speed to a value other then these, the camera will
automatically round the setting down to the nearest valid speed.