Acquisition Control AW00118501000
62 Basler racer Camera Link
6.3 Acquisition Monitoring Tools
The camera includes the acquisition status feature and generates these output signals that you can
use to monitor the progress of line acquisition by the camera:
the exposure active signal
the line trigger wait signal.
The camera also allows selecting the output of the frequency converter module as output signals.
In addition, you can check the camera’s acquisition status (see below).
6.3.1 Exposure Active Signal
The camera’s Exposure Active output signal will go high when the exposure time for each line
acquisition begins and goes low when the exposure time ends. The signal can for example be used
as a flash trigger.
An example of the Exposure Active signal’s behavior on a camera using a rising edge external line
start trigger signal (ExLSTrig) and the timed exposure mode is shown in Fig. 14.
Fig. 14: Exposure Active Signal
Selecting the Exposure Active Signal as the Source Signal for the CLSpare
Output Line Using Basler pylon
You can select the exposure active signal as the source signal for the CL Spare output line:
Use the Line Selector to select the CLSpare line.
Set the value of the Line Source Parameter to the exposure active output signal.
You can set the Line Selector and the Line Source parameter value from within your application
software by using the Basler pylon API. The following code snippet illustrates using the API to set
the selector and the parameter value:
//Select the CL Spare line
Camera.LineSelector.SetValue( LineSelector_ClSpare );
//Set the source signal for the selected line
Camera.LineSource.SetValue( LineSource_ExposureActive );
Exposure
Line N
Exposure
Line N+1
Exposure
Line N+2
ExLStTrig
Signal
Exposure
Active Signal
Not to scale