AW00118501000 Acquisition Control
Basler racer Camera Link 65
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon API and the pylon Viewer, see Section 3.1.1 on page 16.
Selecting the Line Trigger Wait Signal as the Source Signal for the CLSpare
Output Line Using Direct Register Access
To select the line trigger wait signal as the source signal for the CL Spare line via direct register
access:
Set the value of the Line Source CL Spare register to Line Trigger Wait.
For more information about direct register access, see Section 3.2 on page 16.
6.3.4 Input Related Signals as Output Signals
The camera allows selecting the output signal of the frequency converter module and assigning it
to the camera’s CLSpare output line. In this fashion input signals can be passed through a camera
to trigger additional cameras.
In this case, setting a minimum output pulse width may be necessary to ensure output signal
detection.
For more information about selecting the source signal for the CLSpare output line on the camera,
see Section 5.6.2.3 on page 37.
For more information about the minimum output pulse width feature, see Section 5.6.2.1 on
page 36.