AW00104701000 Standard Features
Basler scout light GigE 205
11.14.2 Selecting a Factory Setup as the
Default Set
When the camera is delivered, the Standard Factory Setup will be selected as the default set. You
can, however, select any one of the two factory setups to serve as the default set.
To select which factory setup that will serve as the default set:
Set the Default Set Selector to the Standard Factory Setup or High Gain Factory Setup.
You can set the Default Set Selector from within your application software by using the Basler pylon
API. The following code snippet illustrates using the API to set the selector:
If you want to select the Standard Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_Standard);
If you want to select the High Gain Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_HighGain);
You can also use the Basler pylon Viewer application to easily set the selector.
Selecting which factory setup will serve as the default set is only allowed when the
camera is idle, i.e. when it is not acquiring images continuously or does not have
a single image acquisition pending.
Selecting the standard factory setup as the default set and then loading the default
set into the active set is a good course of action if you have grossly misadjusted
the settings in the camera and you are not sure how to recover. The standard
factory setup is optimized for use in typical situations and will provide good camera
performance in most cases.