AW00104701000 Standard Features
Basler scout light GigE 189
Setting Reverse X
You can enable or disable the reverse X feature by setting the ReverseX parameter value. You can
set the parameter value from within your application software by using the Basler pylon API. The
following code snippet illustrates using the API to set the parameter value:
// Enable reverse X
Camera.ReverseX.SetValue(true);
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameter.
For more information about the pylon Viewer, see Section 3.1 on page 25.
For color cameras, provisions are made ensuring that the effective color filter
alignment will be constant for both, normal and mirror images.
Fig. 50: Using an AOI with Reverse X Mirror Imaging
Normal Image Mirror Image