Basler A400K Manual do Utilizador Página 41

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 194
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 40
Physical Interface
Basler aviator Camera Link 33
Setting the Timer 1 Parameters Using Direct Register Access
To set the timer 1 parameters via direct register access:
Set the value of the Timer Delay Raw Timer 1 register.
Set the value of the Timer Duration Raw Timer 1 register.
A value in a raw register is simply an integer value with no units. To determine what the actual delay
or duration time will be, you must multiply the raw value by the camera’s time base. The time base
on aviator cameras is 1 µs.
For example, if you set the Timer Delay Raw Timer 1 register to 100, the delay time for timer 1 would
be 100 µs (100 x 1 µs = 100 µs).
For more information about changing settings via direct register access, see Section 4 on page 45.
Vista de página 40
1 2 ... 36 37 38 39 40 41 42 43 44 45 46 ... 193 194

Comentários a estes Manuais

Sem comentários