Image Acquisition Control AW00098504000
98 Basler ace Camera Link
You can avoid violating this guideline by using the camera’s Frame Trigger Wait signal to determine
when exposure can safely begin and by properly setting the camera’s Exposure Overlap Time Max
Abs parameter.
For more information about the Frame Trigger Wait signal and the Exposure Overlap Time Max Abs
parameter, see Section 7.6.2.2 on page 104.
For more information about trigger width exposure, see Section 7.3.3.2 on page 87.
For more information about the over trigger error, see Section 10.10 on page 208.